• Quick sample bottle analysis

  • In the lab or in the field monitoring

  • Analysis of fluid moisture and temperature capability

Parker icountBSplus - Bottle Sampler

icountBSplusParker Filtration's CE compliant icountBSplus is a unique and complete solution providing customers with laboratory fluid bottle sampling usen proven on-board, laser based technology. The icountBSplus is a next generation product from Parker's fluid particle analysis and monitoring programme and provides an effective alternative to external laboratory services.

Product features:

  • Quick sample bottle analysis with variable test time options from 15 seconds and volume capacities from 25 ml
  • Repeatable and re-producible result performance to ISO4406:1999, NAS 1638 AS4509E and GOST 17216:2001 (Differential and Cumulative) particle count distributions
  • On-board compressor and 'shop' air capability
  • Environmentally controlled front-loading bottle chamber
  • Selectable 12-language instruction manual menu
  • Analysis of fluid moisture and temperature capability
  • icountBSplus has the capability for on-line fluid measurement configuration as well as off-line fluid sampling
  • Design concept allowing for portability. DC and rechargeable battery pack power option built in
  • CE compliant
  • Fluid resistant touch type screen panel
  • On-board thermal printer
  • 500 test memory (fully downloadable)

The icountBSplus has been developed using the latest industrial design and manufacturing techniques, creating a system that integrates state of the art technology with dependable and precise measurement and analysis processes. Built by engineers, for engineers, the icountBSplus gives you a valuable and extremely effective tool for use in many different applications: Agriculture, Defence, Aerospace, Oil & Gas, Construction, Marine, Power Generation & Industrial.

Benefits:

  • Low cost solution for monitoring fluid life and reducing machine downtimes
  • Easy to set up and use this CE compliant instrument
  • Selectable 12 language instruction manual menu
  • Optional on-line fluid measurement capability
  • Independent monitoring of contamination
  • Calibration to ISO procedures

Specifications

Principle of operationLaser diode optical detection of actual particulates
DimensionsH 530 mm x W 210 mm x D 410 mm
WeightApprox 18 kg
Operating temperature and humidity+5°C to +60°C (-41°F to +140°F)
20 - 85% RH (tested at 30°C (86°F), non-condensing)
Storage temperature and humidity-40°C to +90°C (-40°F to +194°F)
10 - 90% RH (tested at 30°C (86°F), non-condensing)
Moisture sensor calibration± 5% RH (over a compensated temperature range of +10°C to +80°C (+50°F to +176°F)
Moisture sensor stability ± 2% RH typical at 50% RH in one year
International codesISO 7 to 21, NAS 0 to 12, AS 0 to 12
Contamination standardsRefer to Parker 'Guide to Contamination Standards' (DD0000015) on CD
MTD: ISO 4406:1999; NAS 1638; AS4059E (Differential); AS4509E (Cumulative)
ACFTD: ISO 4406:1987; ISO4406:1991; NAS 1638; AS4509E (Differential); AS4509E (Cumulative); GOST 17216:2001
Calibration MTD: via a certified primary ISO 11171 automatic particle detector using ISO 11943 principles, with particle distribution reporting to ISO 4406:1996
ACFTD: fully traceable to gravimetric first principles
RecalibrationContact Parker Hannifin for advice
Fluid compatibilityMineral-based oils and petroleum-based fuel. Contact Parker Hannifin for advice
Fluid managementSelectable on screen between 25 m to 100 ml
Viscosity range1 to 300 cSt
Working pressure3 bar maximum input pressure, if used on-line. Contact Parker Hannifin for further advice
Flow range through icountBSplusTest: 60 ml/min
Connection interface (on-line)INLET: 6 mm push-fit, DRAIN: 4 mm push-fit
Fluid operating temperature (oil)+5°C to +70°C (-41°F to 176°F)
Fluid operating temperature (fuel)+20°C to +70°C (-4°F to 158°F)
Sample bottle sizeSee Parker ACC Spares list. Contact Parker Hannifin for advice
Flush sample sizeSelectable option within the icountBS software: 25 ml to 100 ml
Memory storage500 tests (Integrated Warning Level)
PrinterThermal dot line printer - see ACC spares list for replacement paper
Battery typePolymer Lithium Ion Battery pack (ACC6NW032)
Power requirementsIntegrated supply into the icountBSplus unit
CertificationCE Certified. Supplied with EC Declaration of Conformity Certificate

Ordering Information

IBS3000iBSplus (online)
IBS3100iBSplus (offline)

Accessories

ACC6NW001Sample Bottle, 250ml (2pcs)
ACC6NW002Sample Bottle, 250ml (100pcs)
ACC6NW003Vapour / Waster Bottle
ACC6NW005Printer Paper Reel (1pc)
ACC6NW009Waste Tube, Clear - 1m
ACC6NW010Vapour Hose, Blue, 1m
ACC6NW020iBS Transit Case
ACC6NW023Power Cable (UK)
ACC6NW028Drip Tray
ACC6NW031Stylus Pen Pack (3pcs)
SER.MISC.067Verification Fluid (2 x 500ml) - SIX MONTH SHELF LIFE
ACC6NN031Low Pressure Hose, 1.5m
ACC6NN033Blanking Plugs

For more information please contact Parker Hannifin HFDE by emailing filtrationinfo@parker.com

Oil Analysis

Latest News

Parker Kittiwake Launches New CAT Fines Test Kit
Test kit detects catalytic fines to prevent irreparable damage to fuel pumps, injectors, piston ring... Read More...
Switching Fuel Oil and the Risk of Loss of Propulsion
Nearly nine months have passed since the 0.1% sulphur limit for marine fuels in designated Emissions... Read More...
Measuring Ferrous Wear: the FWM vs. the Analex fdMplus
When it comes to detecting and analysing machine wear, testing for ferrous density – the prese... Read More...